Portable power station runtime calculator
Pick a station and a load. We use 85% of rated capacity to account for inverter losses and a healthy depth of discharge.
Usable watt-hours = rated capacity x 0.85. Runtime = usable watt-hours / load in watts. Choose a station and a load to see the result.
Reference
Runtime at a glance
The same 85% rule, applied to three common loads. These are planning estimates, not lab measurements.
| Station | Rated | Usable | Fridge (75W) | CPAP (40W) | Heater (1,500W) |
|---|---|---|---|---|---|
| EcoFlow DELTA Pro 3 | 4,096 Wh | 3,482 Wh | 46 hr | 3.6 days | 2.3 hr |
| Bluetti Elite 400 | 3,840 Wh | 3,264 Wh | 44 hr | 3.4 days | 2.2 hr |
| Anker SOLIX F3800 Plus | 3,840 Wh | 3,264 Wh | 44 hr | 3.4 days | 2.2 hr |
| EcoFlow DELTA 3 Ultra Plus | 3,072 Wh | 2,611 Wh | 35 hr | 2.7 days | 1.7 hr |
| Anker SOLIX F2600 | 2,560 Wh | 2,176 Wh | 29 hr | 2.3 days | 1.5 hr |
| Bluetti AC200P L | 2,304 Wh | 1,958 Wh | 26 hr | 2.0 days | 1.3 hr |
| Bluetti Elite 200 V2 | 2,073.6 Wh | 1,763 Wh | 24 hr | 44 hr | 1.2 hr |
| EcoFlow DELTA 3 Max Plus | 2,048 Wh | 1,741 Wh | 23 hr | 44 hr | 1.2 hr |
| Anker SOLIX C2000 Gen 2 | 2,048 Wh | 1,741 Wh | 23 hr | 44 hr | 1.2 hr |
| Jackery HomePower 2000 Plus v2 | 2,048 Wh | 1,741 Wh | 23 hr | 44 hr | 1.2 hr |
| Jackery Explorer 2000 v2 | 2,042 Wh | 1,736 Wh | 23 hr | 43 hr | 1.2 hr |
| Jackery Explorer 1000 v2 | 1,070 Wh | 910 Wh | 12 hr | 23 hr | 36 min |
| EcoFlow DELTA 3 Plus | 1,024 Wh | 870 Wh | 12 hr | 22 hr | 35 min |
| Anker SOLIX C1000 Gen 2 | 1,024 Wh | 870 Wh | 12 hr | 22 hr | 35 min |
| Bluetti Elite 100 mini | 1,004 Wh | 853 Wh | 11 hr | 21 hr | 34 min |
| Goal Zero Yeti 1000 Core | 983 Wh | 836 Wh | 11 hr | 21 hr | 33 min |
| EcoFlow RIVER 3 Plus | 286 Wh | 243 Wh | 3.2 hr | 6.1 hr | 10 min |
A real fridge cycles, so its average draw is lower than its running wattage. A heater runs continuously. Read the fridge runtime guide.
Method
What the calculator does and does not model
It is a planning tool, not a guarantee.
It models
Rated capacity, an 85% usable-energy factor, constant average load, and the number of days you want to run without recharging.
It does not model
Startup surge, duty cycles, temperature, inverter efficiency curves, or simultaneous loads. Use the load planner for a multi-appliance estimate.
It rounds conservatively
Most LFP stations can deliver more than 85% of rated capacity in ideal conditions. We use 85% so the estimate holds up in real use.
FAQ
Calculator questions
Why 85% and not 100%?
Inverter losses, battery management overhead, and a healthy depth of discharge reduce delivered energy. Using 85% keeps estimates realistic and comparable across brands.
Does the calculator account for startup surge?
No. Check the station's surge rating against the appliance's locked-rotor or startup current, especially for pumps, compressors, and air conditioners.
Can I run multiple appliances?
Add their average wattages together and enter the total. For a more structured estimate, use the outage load planner.
Why do the results differ from the manufacturer's runtime chart?
Manufacturers often test at a fixed load and may use a different usable-energy assumption. Our estimates are conservative and consistent across brands.
Next
Planning for more than one appliance?
The outage planner adds up a whole essentials list and recommends a capacity.