Portable power station runtime calculator

Pick a station and a load. We use 85% of rated capacity to account for inverter losses and a healthy depth of discharge.

How the math works

Usable watt-hours = rated capacity x 0.85. Runtime = usable watt-hours / load in watts. Choose a station and a load to see the result.

Reference

Runtime at a glance

The same 85% rule, applied to three common loads. These are planning estimates, not lab measurements.

Runtime for every station at 75W, 40W, and 1,500W
StationRatedUsableFridge (75W)CPAP (40W)Heater (1,500W)
EcoFlow DELTA Pro 34,096 Wh3,482 Wh46 hr3.6 days2.3 hr
Bluetti Elite 4003,840 Wh3,264 Wh44 hr3.4 days2.2 hr
Anker SOLIX F3800 Plus3,840 Wh3,264 Wh44 hr3.4 days2.2 hr
EcoFlow DELTA 3 Ultra Plus3,072 Wh2,611 Wh35 hr2.7 days1.7 hr
Anker SOLIX F26002,560 Wh2,176 Wh29 hr2.3 days1.5 hr
Bluetti AC200P L2,304 Wh1,958 Wh26 hr2.0 days1.3 hr
Bluetti Elite 200 V22,073.6 Wh1,763 Wh24 hr44 hr1.2 hr
EcoFlow DELTA 3 Max Plus2,048 Wh1,741 Wh23 hr44 hr1.2 hr
Anker SOLIX C2000 Gen 22,048 Wh1,741 Wh23 hr44 hr1.2 hr
Jackery HomePower 2000 Plus v22,048 Wh1,741 Wh23 hr44 hr1.2 hr
Jackery Explorer 2000 v22,042 Wh1,736 Wh23 hr43 hr1.2 hr
Jackery Explorer 1000 v21,070 Wh910 Wh12 hr23 hr36 min
EcoFlow DELTA 3 Plus1,024 Wh870 Wh12 hr22 hr35 min
Anker SOLIX C1000 Gen 21,024 Wh870 Wh12 hr22 hr35 min
Bluetti Elite 100 mini1,004 Wh853 Wh11 hr21 hr34 min
Goal Zero Yeti 1000 Core983 Wh836 Wh11 hr21 hr33 min
EcoFlow RIVER 3 Plus286 Wh243 Wh3.2 hr6.1 hr10 min

A real fridge cycles, so its average draw is lower than its running wattage. A heater runs continuously. Read the fridge runtime guide.

Method

What the calculator does and does not model

It is a planning tool, not a guarantee.

It models

Rated capacity, an 85% usable-energy factor, constant average load, and the number of days you want to run without recharging.

It does not model

Startup surge, duty cycles, temperature, inverter efficiency curves, or simultaneous loads. Use the load planner for a multi-appliance estimate.

It rounds conservatively

Most LFP stations can deliver more than 85% of rated capacity in ideal conditions. We use 85% so the estimate holds up in real use.

FAQ

Calculator questions

Why 85% and not 100%?

Inverter losses, battery management overhead, and a healthy depth of discharge reduce delivered energy. Using 85% keeps estimates realistic and comparable across brands.

Does the calculator account for startup surge?

No. Check the station's surge rating against the appliance's locked-rotor or startup current, especially for pumps, compressors, and air conditioners.

Can I run multiple appliances?

Add their average wattages together and enter the total. For a more structured estimate, use the outage load planner.

Why do the results differ from the manufacturer's runtime chart?

Manufacturers often test at a fixed load and may use a different usable-energy assumption. Our estimates are conservative and consistent across brands.

Next

Planning for more than one appliance?

The outage planner adds up a whole essentials list and recommends a capacity.